High Bay Lighting Guide — Lux Targets, Spacing and Fixture Choice for Warehouses
High bay lighting fails in two directions: not enough lux (workers slow down, errors climb) or too many fixtures (your energy bill grows forever). Both come from skipping the photometric step and guessing from wattage. This guide gives importer- and facility-manager-level rules of thumb — then the exact inputs your supplier needs to run a real dialux-style layout instead of guessing.
Written by the GDtokin Sourcing Team · Updated October 2026
1. Lux Targets by Space (EN 12464-1 Aligned)
| Area | Target lux | Uniformity (U0) | Notes |
|---|---|---|---|
| Bulk storage, low activity | 100–150 | 0.25–0.40 | Aisle-only lighting acceptable |
| Racking aisles, forklift traffic | 150–200 | 0.40 | Aisle-focused optics beat brute wattage |
| Packing & sorting benches | 300–500 | 0.60 | Task lighting on benches may supplement |
| Inspection / QC stations | 750–1000+ | 0.70 | Localized high-CRI fixtures |
| Workshop / assembly hall | 300–500 | 0.60 | UGR < 22 to control high-bay glare |
Retrofit buyers: converting from 400W metal halide? A 150W UFO LED high bay typically replaces it at 6–8 m mounting; at 10–12 m, step to 200–240W. Lumen-per-watt matters less than lumens-landed-on-floor — that is why the layout step exists.
2. UFO vs Linear High Bay
UFO high bays suit open areas, high ceilings and spot replacement of round HID fixtures: compact, good heat sinking, optics from 60° to 120°. Linear high bays suit racking aisles and rectangular workshop bays: the elongated shape spreads light along the aisle axis, often cutting fixture count 10–20% in narrow aisles. A quick heuristic: if the space is wider than it is tall, linear wins; if ceilings exceed 9 m and the floor plate is open, UFO wins. Both live in our LED high bay line with 5-year driver warranties.
3. Spacing Rules Before You Model
- Mounting height 6–8 m: spacing 1.2–1.5× mounting height for 90°–120° optics; roughly equal to height for 60° optics.
- Aisle racking: run linear fixtures parallel to aisles, one row per aisle for aisles ≤ 3 m wide; alternate rows in stagger for very tall racking.
- Perimeter kick: add fixtures within 1–1.5 m of walls or the boundary goes gray on camera — and on forklift dashcams.
- Sensors: aisle-by-aisle microwave sensors routinely cut measured energy 40–60% in low-traffic warehouses; spec them with the fixtures, not retrofitted, so dim curves match drivers.
4. What Your Supplier Needs for a Real Layout
Five inputs: floor dimensions and mounting height, racking plan (aisle widths and orientation), target lux per zone, local voltage and control preferences (on/off, 1-10V, DALI, sensor), and any photometric file format your consultant requires (IES/LDT). With those we return a fixture schedule with counts, positions and predicted lux — before you commit a single container. Our production floor runs under exactly this method, so we ship layouts we have validated on our own ceiling.
Send your warehouse dimensions for a free layout. Related: LED floodlights for yard and facade, private-label high bay programs, and the importer buying guide.