OEM / ODM Welcome | Reply within 24h
Home / Products / Industrial Fans

Industrial Fans — HVLS 8ft to 24ft, Direct-Drive

High-volume low-speed fans for warehouses, workshops, gyms and agricultural buildings. Permanent-magnet direct drive, no gearbox to service.

Industrial Fans

Overview

Industrial Fans made in our Zhongshan factory

A higher-ticket line that complements the residential catalog: same factory discipline, different sales channel — industrial distributors and facility contractors.

8ft–24ftPMSM direct drive0.75–1.5kWLow noise
  • Permanent-magnet direct driveNo gearbox, no oil changes, fewer service calls.
  • Up to 24ft diameterOne fan covers up to 20,000 sq ft of floor area.
  • Very low noiseUnder 45 dB(A) at 10ft — usable in occupied facilities.
  • Energy efficient0.75–1.5 kW replaces a bank of pedestal fans.
  • Safety redundancyDual-suspension and aircraft-grade cables as standard.
  • Variable frequency driveSoft start, programmable speeds, remote or wall panel.

Specifications

Standard platform specifications

These are the defaults we quote from. Every row below is adjustable inside an OEM or ODM program.

Parameter Standard
Diameter 8ft / 12ft / 16ft / 20ft / 24ft (2.4–7.3 m)
Motor PMSM permanent-magnet direct drive
Power 0.75 kW / 1.1 kW / 1.5 kW
Voltage 120V single phase · 220–240V · 380–480V three phase
Blades 5 or 6, aerofoil section, aluminium alloy
Control VFD with wall panel, remote, or building automation input
Noise ≤ 45 dB(A) at 10ft
Max coverage Up to 1,850 m² (20,000 sq ft) per fan
Mounting I-beam, purlin, or truss mount
Safety Dual suspension, safety cable, redundant fasteners
Certification target UL / ETL, CE available

Specifications are indicative and confirmed in the final quotation and approved sample.

Manufacturing

How your Industrial Fans order is built and tested

Every stage below happens on our own floor in Guzhen Town. Nothing in this list is subcontracted,
which is why a colour change, a motor change or a packaging change does not restart the queue.

Industrial Fans production and quality control flow in our Zhongshan factory

Heavy motor assembly

Motors for HVLS units are assembled and tested on a dedicated line, because the duty cycle and load are a different order of magnitude from a residential fan.

Blade set assembly and balance

Large blade sets are balanced as a complete assembly, not blade by blade. Unbalance at this diameter becomes structural, not cosmetic.

Load and run-in test

Units are run under load before packing so bearing and drive problems surface on our floor.

Structural inspection

Mounting points and welds are inspected before the unit is crated.

Selection guide

Choosing the right Industrial Fans for your market

Four decisions that change the price, the compliance path and the shipping volume. Confirm these
before tooling or artwork is committed.

Airflow by building volume

HVLS sizing works from building volume and height, not from a simple square-metre figure. Send the building dimensions and we size the unit.

Mounting and structure

Roof structure, purlin spacing and mounting height determine the correct mount. This is confirmed before quotation because it changes the delivered specification.

Control and integration

Variable speed control, group control and building-management integration are each a different configuration and need confirming before the control panel is specified.

Installation support

Confirm whether the buyer installs with their own crew or needs installation drawings and a supervision pack. Both are quoted.

Customization

What we can change for your brand

Blade and finish

Mill finish, powder coated, or branded blade profile.

Control integration

0–10V, Modbus or BACnet interface for BMS.

VFD branding

Your logo on the drive panel and enclosure.

Crating

Export crating with crane lift points for site delivery.

Applications

Where this product sells

Warehouses & distribution

Destratification in 30ft clear-height buildings.

Manufacturing

Air movement without disturbing dust or welding arcs.

Agricultural buildings

Dairy and poultry ventilation and heat destratification.

Fitness & sports halls

Comfort cooling at low noise level.

Packing and documentation

What ships with the goods

HVLS units ship crated with the blade set, mounting hardware, control panel and installation drawings. Crating is dimensioned for a standard container and is confirmed with the pre-shipment sample drawings so the receiving site can plan lifting equipment.

Carton and pallet dimensions, the inspection record and the component
certificates travel with the shipment. Anything the destination market requires on the label is
confirmed at the pre-production sample stage.

FAQ

Buyer questions

Do HVLS fans need a gearbox?
Not ours — permanent-magnet direct drive removes the gearbox entirely, which removes the main maintenance item.
Can one fan serve a large warehouse?
A 24ft fan covers up to about 20,000 sq ft of floor when mounted at 20ft or higher. We will advise on the layout if you share your building dimensions.
Is three-phase power required?
No. Single-phase 120V and 220–240V models are available alongside three-phase.
Do you supply installation hardware?
Yes, mounting brackets, extension tubes and safety cables are supplied. Site installation is by your contractor.
Products

Available Industrial Fans in this category

See all Industrial Fans

Related

Other categories from the same factory

Ceiling Fan Lights

Ceiling Fan Lights

Blade + LED light in one fixture. Remote & app control.

View specs

Ceiling Fans

Ceiling Fans

52″–60″ AC and DC ceiling fans, no light kit.

View specs

Smart Fan Lights

Smart Fan Lights

Wi-Fi / BLE fan lights with Alexa & Google Home.

View specs

Send your spec, get a real quotation

Include target market, quantity and any certification requirement. We reply with price, lead time (within China), MOQ and the documentation we can support.